Dual RF LDMOS Bias Controllers
with I 2 C/SPI Interface
Clock Mode 00
In clock mode 00, power-up, acquisition, conversion,
and power-down are all initiated by writing to the Analog-
to-Digital Conversion register and performed automati-
cally using the internal oscillator. This is the default clock
mode. The ADC sets the BUSY output high, powers up,
scans all requested channels, stores the results in the
FIFO, and then powers down. After the scan is complete,
BUSY is pulled low and the results for all the command-
ed channels are available in the FIFO.
Clock Mode 01
In clock mode 01, power-up, acquisition, conversion,
and power-down are all initiated by setting CNVST low
for at least 40ns. Conversions are performed automati-
cally using the internal oscillator. The ADC sets the
BUSY output high, powers up, scans all requested
channels, stores the results in the FIFO, and then pow-
ers down. After the scan is complete, BUSY is pulled
low and the results for all the commanded channels are
available in the FIFO.
Clock Mode 11
In clock mode 11, conversions are initiated one at a
time through CNVST in the order shown in Table 1 and
performed using the internal oscillator. In this mode, the
acquisition time is controlled by the time CNVST is
brought low. CNVST is resynchronized by the internal
oscillator, which means there is a one-clock-cycle
uncertainty (typically 320ns) in the exact sampling
instant. Different timing parameters apply depending
whether the conversion is temperature, voltage, using
the external reference, or using the internal reference.
Table 1. Order of ADC Conversion Scan
For a temperature conversion, set CNVST low for at
least 40ns. The BUSY output goes high and the temper-
ature conversion results are available after an addition-
al 94μs (when BUSY goes low again). Thus, the
worst-case conversion time of the initial temperature
sensor scan (allowing the internal reference to settle) is
175μs. Subsequent temperature scans only take 85μs
worst case as the internal reference and temperature
sensor circuits are already powered.
For a voltage conversion while using an internal or
external reference, set CNVST low for at least 2μs but
less than 6.7μs. The BUSY output goes high and the
conversion results are available after an additional
7.5μs (typ) when BUSY goes low again.
Continuous conversion is not supported in this clock
mode (see the ADCCON (Write) section).
Changing Clock Modes During ADC Conversions
If a change is made to the clock mode in the Device
Configuration register while the ADC is already per-
forming a conversion (or series of conversions), the fol-
lowing descriptions show how the MAX1385/MAX1386
respond:
? CKSEL = 00 and is then changed to another value
The ADC completes the already triggered series of
conversions and then goes idle. The BUSY output
remains high until the conversions are completed.
The MAX1385/MAX1386 then respond in accor-
dance with the new CKSEL mode.
? CKSEL = 01 and is then changed to another value
If waiting for the initial external trigger, the
MAX1385/MAX1386 immediately exit clock mode
01, power down the ADC, and go idle. The BUSY
output stays low and waits for the external trigger. If
ORDER OF SCAN
1
2
3
4
5
6
7
DESCRIPTION OF CONVERSION
Internal device temperature
External diode 1 temperature
PGAOUT1 for current sense
ADCIN1
External diode 2 temperature
PGAOUT2 for current sense
ADCIN2
a conversion sequence has started, the ADC com-
pletes the requested conversions and then goes
idle. The BUSY output remains high until the conver-
sions are completed. The MAX1385/MAX1386 then
respond in accordance with the new CKSEL mode.
? CKSEL = 11 and is then changed to another value
If waiting for an external trigger, the MAX1385/
MAX1386 immediately exit clock mode 11, power
down the ADC, and go idle. The BUSY output stays
low and waits for the external trigger.
______________________________________________________________________________________
19
相关PDF资料
MAX1470EUI+T IC RECEIVER 315MHZ 28-TSSOP
MAX1470EVKIT-315 EVAL KIT FOR MAX1470 315MHZ
MAX1471EVKIT-315 EVAL KIT FOR MAX1471 315MHZ
MAX1472EVKIT-433# EVAL KIT MAX1472
MAX1473EVKIT-433 EVAL KIT MAX1473
MAX1479EVKIT-315 EVAL KIT FOR MAX1479 315MHZ
MAX19700EVKIT EVAL KIT FOR MAX19700
MAX19985AETX+T IC MIXER DOWNCONV 36-TQFN-EP
相关代理商/技术参数
MAX1385BUTM+T 功能描述:射频放大器 2Ch RF LDMOS Bias Controller RoHS:否 制造商:Skyworks Solutions, Inc. 类型:Low Noise Amplifier 工作频率:2.3 GHz to 2.8 GHz P1dB:18.5 dBm 输出截获点:37.5 dBm 功率增益类型:32 dB 噪声系数:0.85 dB 工作电源电压:5 V 电源电流:125 mA 测试频率:2.6 GHz 最大工作温度:+ 85 C 安装风格:SMD/SMT 封装 / 箱体:QFN-16 封装:Reel
MAX1385EVC16 功能描述:放大器 IC 开发工具 MAX1385 Eval Kit RoHS:否 制造商:International Rectifier 产品:Demonstration Boards 类型:Power Amplifiers 工具用于评估:IR4302 工作电源电压:13 V to 23 V
MAX1385EVKIT+ 功能描述:射频开发工具 MAX1385 Eval Kit RoHS:否 制造商:Taiyo Yuden 产品:Wireless Modules 类型:Wireless Audio 工具用于评估:WYSAAVDX7 频率: 工作电源电压:3.4 V to 5.5 V
MAX1386AETM+ 制造商:Maxim Integrated Products 功能描述:
MAX1386CAP+T 制造商:Maxim Integrated Products 功能描述:+-15 KV ESD-PROTECTED, EMC-COMPLIANT, 230KBPS - Tape and Reel
MAX138C/D 功能描述:模数转换器 - ADC RoHS:否 制造商:Texas Instruments 通道数量:2 结构:Sigma-Delta 转换速率:125 SPs to 8 KSPs 分辨率:24 bit 输入类型:Differential 信噪比:107 dB 接口类型:SPI 工作电源电压:1.7 V to 3.6 V, 2.7 V to 5.25 V 最大工作温度:+ 85 C 安装风格:SMD/SMT 封装 / 箱体:VQFN-32
MAX138CMH 制造商:Maxim Integrated Products 功能描述:44 PINS MQFP PKG - Bulk
MAX138CMH+ 制造商:Maxim Integrated Products 功能描述:ADC SGL DUAL SLOPE 3 1/2DIGIT LCD 44MQFP - Rail/Tube